How to Solve FANUC Alarm 413?

NOV. 26, 2026

FANUC Alarm 413 (SERVO ALARM: n-th AXIS – LSI OVERFLOW) means that the servo error register for that axis has overflowed.

As per the FANUC maintenance manual, this alarm is generally caused by incorrect servo parameters. It could be down to the motor configuration, the feedback pulse settings or one of the various servo parameter calculations. Before you replace the servo drive or the motor, check the relevant parameters and ensure they match the actual machine configuration.

How to Solve FANUC Alarm 413?

What does FANUC Alarm 413 mean?

FANUC Alarm 413 is generated when the contents of the error register for the axis in question have exceeded the range of −2^31 to +2^31.

The error register is part of the servo control system. If its calculated value is outside the supported range then the CNC will generate an LSI Overflow alarm.

FANUC will identify incorrectly set parameters as the likely cause. So this alarm should be treated first as a servo parameter or configuration issue rather than as any kind of direct evidence of a hardware failure.

The alarm message will also identify the affected axis. An X-axis alarm for instance would require you to check the servo configuration and parameters for the X-axis.

Common Causes of FANUC Alarm 413

1. Incorrect Servo Parameter Settings

Incorrect parameter values can result in the digital servo system carrying out abnormal calculations.

This can occur after servo parameter init, parameter restore or manual parameter change. Always ensure the parameters match the motor and machine that you actually have installed.

2. Incorrect Feedback Pulse Settings

The number of position and velocity feedback pulses has an effect on the servo calculations.

If those values don't match the actual motor and feedback device configuration then the internal calculations could end up being invalid or going outside of their supported range.

3. Incorrect Flexible Feed Gear Settings

For machines using a flexible feed gear the numerator and denominator settings must match the actual mechanical transmission and detection arrangement.

Incorrect gear ratio settings can lead to incorrect feedback scaling and servo parameter calculation problems.

4. Incorrect Motor or Detector Configuration

After replacing a servo motor, pulse coder or separate position detector the associated servo parameters may need to be checked.

If the selected motor configuration and feedback settings don't match the installed hardware the servo system may not work correctly.

3. How to Troubleshoot FANUC Alarm 413 Step by Step

Step 1: Confirm the Alarm and Identify the Affected Axis

First, confirm that the CNC displays:

SERVO ALARM: n-th AXIS – LSI OVERFLOW

Record the affected axis, the CNC model, the servo drive model and the servo motor model.

Also check that the alarm came on following a parameter change, a servo motor change, an encoder change or some CNC maintenance.

Step 2: Back Up and Review the Servo Parameters

Before you change any settings, make a backup of the current CNC parameters.

Compare the affected axis parameters against the original machine parameter records or a verified backup.

Pay particular attention to parameters related to:

  • Motor number and motor configuration
  • Position feedback pulses
  • Velocity feedback pulses
  • Flexible feed gear settings, where applicable
  • Separate detector configuration, where applicable

Don't just copy the parameter values from one machine on to another simply because it's using the same FANUC motor and amplifier.

Step 3: Check the Position and Velocity Feedback Pulse Settings

For applicable FANUC α-series systems, the parameter manual identifies the following parameters for Series 16 and 18:

  • Parameter No. 2023: Number of velocity pulses.
  • Parameter No. 2024: Number of position pulses.

Check that the settings match those of the motor and feedback device actually installed.

The required values will vary according to the detection unit, motor configuration and machine transmission. See the relevant FANUC parameter manual for the correct values rather than using a generic setting.

Step 4: Verify the Flexible Feed Gear Settings

If it's using a flexible feed gear then check the associated parameters.

For FANUC Series 16 and 18, the flexible feed gear numerator and denominator are specified by:

  • Parameter No. 2084: Flexible feed gear numerator.
  • Parameter No. 2085: Flexible feed gear ratio.

For other FANUC generations the parameter numbers will be different.

Confirm that the ratio is in fact what the actual mechanical transmission and feedback arrangement is. Any incorrect values should only be corrected after the appropriate calculation has been carried out and the machine specs have been checked.

Step 5: Check Recent Motor or Encoder Replacements

If Alarm 413 appears following replacement of a servo motor, pulse coder or individual detector, ensure the new component is in line with the original configuration.

Look at the motor ID, the feedback resolution, the detection method and the associated parameter settings.

A component replacement does not in itself guarantee that the existing servo parameters are appropriate.

Step 6: Investigate the Servo System if Necessary

If the parameter settings have been checked and the alarm is still there then further diagnosis will be required.

Check the relevant servo diagnostic information and look at the servo amplifier, the feedback device and the CNC servo control system as appropriate.

Don't replace any hardware on the basis of Alarm 413 alone. You need to establish what the actual fault is before you go any further with repairs or replacement.

Common Mistakes When Fixing FANUC Alarm 413

Avoid these common troubleshooting mistakes:

  • Changing parameters without a backup: always save the original settings first.
  • Copying parameters from similar machines: different motors, different encoders and different mechanical set ups will all have different values.
  • Ignore the feedback pulse settings (position and velocity pulse values must match the actual feedback settings).
  • Replacing the hardware too early: incorrect parameter settings can cause the alarm to be triggered even if the servo amplifier is in fact working perfectly.
  • Don't confuse Alarm 413 with Alarm 414, 415 or 417.

A systematic parameter check is far more reliable than simply replacing the component on the basis of the alarm number.

Safety Precautions During Troubleshooting

Back up all the CNC parameters prior to making any changes. Use the appropriate FANUC parameter manual for the control system and servo software version that you have installed.

Before you go any further and start looking at the servo amplifiers, the motors or the electrical connections themselves you must follow the machine manufacturer's shutdown and electrical isolation procedures. You must also observe the required waiting time for the residual voltage to discharge.

Parameter adjustments and electrical testing should be carried out by qualified CNC technicians.

Should you repair or replace the FANUC servo components?

The right answer is going to be dictated by the diagnostic results.

If Alarm 413 is due to incorrect servo parameters then correcting the configuration will fix the problem without any hardware being required.

If the alarm continues once the parameters have been checked, further testing may be required to establish whether the servo amplifier, the motor feedback device or the CNC control hardware itself is at fault.

When you need a replacement, make sure you have the full part number and that it's compatible with the existing CNC system. For used parts, also check the test status and the warranty.

How SongWei CNC Can Help

Songwei CNC supply new and used FANUC CNC spares including servo amplifiers, servo motors, encoders, CNC control boards and all the associated bits.

We also offer testing and repair of FANUC parts to support CNC machine maintenance and trouble shooting.

If you need help with FANUC Alarm 413 then please provide your CNC model, the axis in question, the servo motor and amplifier models, the alarm info and any recent parameter or component replacements. That will help us to understand what the problem is and what the likely repair or replacement options are.

Conclusion

FANUC Alarm 413 (LSI OVERFLOW) means that the servo error register for that axis has overflowed. Incorrect servo parameters are a very common cause.

Firstly identify the axis in question and check the motor configuration, the feedback pulse settings and (if relevant) the flexible feed gear parameters. If the parameters are all correct and the alarm is still occurring then the associated servo hardware will need to be checked.

Accurate parameter verification prior to component replacement will go a long way to avoiding unnecessary repair costs and machine downtime.

Related Product Types

If you found this article interesting, you may want to know more about these related product types. 

Contact Us to Maximize Your Profit

Enter part information below to check price and availability.

Usually ship by UPS or DHL with delivery around 3 working days.

All parts are tested OK before shipping out with a 12-month warranty.

Provide technology guidance service upon receiving the part.

CONTACT US
Thank you! Your message has been sent.
Unable to send your message. Please fix errors then try again.

Search