5 Ways to Resolve Fanuc SV0433 Alarm

JUN. 9, 2025

Fanuc SV0433 alarm pops up on your machine? Don't panic, this is a problem that many people have actually encountered. Although it sounds scary, in most cases it can be solved by a simple check without replacing the entire servo amplifier.

We at Songwei help our customers deal with all kinds of Fanuc alarms all year round, and SV0433 is one of the most common ones. The following will teach you a few simple and effective troubleshooting methods, can be solved by themselves as much as possible do not spend money.

5 Ways to Resolve Fanuc SV0433 Alarm
What Is SV0433 Alarm?
Simply put: servo amplifier overcurrent, or a short circuit.

Common causes include:
* Motor suddenly pulls high current.
* Short circuit in the motor wires or inside the amplifier.
* Wiring problems or unstable ground.
* Damage to internal parts of the amplifier.

This alarm is typically found on machines using Fanuc Alpha, Beta, or i-Series drive systems. If left untreated, it can burn more parts and slow down the entire production line.
 
1. See if There Are Any Problems with the Power and Servo Cables First
Start by checking the most problematic areas: are the cables connected, broken, or crushed?

Focus on checking:
* Amplifier to motor power line.
* Signal line, encoder feedback line.
* Ground wire, shielded wire.
* Any burnt, bent, or torn outer jacket.

šŸ’” Tip: Use a multimeter to measure the conduction, or see if there is any leakage in the insulation. A large part of the SV0433 problems we have repaired are actually wire problems.
 
2. Check the Servo Motor Itself for Shorts
If the wires are OK, the next step is to suspect the motor. Here's what you can do:

* Disconnect the motor from the amplifier first.
* Measure the three-phase resistance (U-V, V-W, W-U).
* Then measure the resistance of each phase to ground.
* If the values are very different, you probably have a short in the motor.

If you are not sure, you can also send it to us Songwei to do the dynamic test with load, which is more accurate and can avoid misjudgment.
 
3. Power off and Restart to See if It's an Occasional Fault
Sometimes this alarm is triggered by an instantaneous high impulse current or an overload of a machine action. You can try to restart:

* Completely shut down the machine, wait for five to ten minutes.
* Clear the alarm in the control panel after powering up the machine again.
* If you can enter the "Test Modeā€ or "Diagnostic Modeā€, you can try to run the machine slowly.

If it returns to normal after reboot, it may be an occasional problem. If it occurs frequently, then you must continue to investigate.
 
4. Take a Close Look at the Servo Amplifier to See if It's Burned
The amplifier itself is bad, which is also a common cause. You can keep an eye out for:

* If there are no burn marks, bulging capacitors, circuit board discoloration?
* Is there any error code LED on the driver module?
* When powering up, if there is no response at all?

When we repair the Fanuc amplifier, we will do the whole machine simulation on our Fanuc test bench, can check some internal damage that can not be seen on the surface.

5. Can't Find the Problem? Get a Professional
If you've checked the cables, motor, and amplifier and the problem is still there, then stop guessing and get someone who knows what they're doing to take a look for you.

You can:
* Try a different spare part (if you have one on hand).
* Send the motor and amplifier to Songwei for inspection.
* We offer Fanuc drives and motors with warranty, and we can also repair damaged parts for you.
* After repairing, we will also give you a fault report, so that you can avoid the same problem next time.
 
How Can I Prevent the Sv0433 Alarm from Recurring?
It's one thing to fix it, it's even more important not to have the problem happen over and over again. You can do these:

* Regularly check the motor wires and signal wires for aging or loosening.
* Keep the control cabinet clean and ventilated to avoid dust accumulation or overheating.
* Use a regulated power supply or add a power filter.
* Idle or spare parts are recommended to do regular "no-load run-inā€ or diagnostic tests.

We can help you to do a whole set of preventive maintenance program, but also can provide remote technical support, if you need to contact at any time.

Why Do More and More Customers Come to Us for Fanuc Repair? 

We are not a "parts onlyā€ company, we are a hands-on repair service provider:

* Specialized Fanuc test platform, Alpha, Beta systems can be run.
* All repaired parts are tested before shipment, so customers can use them as soon as they receive them.
* All repaired parts have warranty.
* Spare parts in stock and shipped globally, quickly.
* Not only Fanuc, we are familiar with Siemens, Mitsubishi, Heidenhain, OKUMA and other common brands.

Fanuc SV0433 Alarm keeps jumping? Alarm keeps tripping? Don't waste time, hurry to contact Songwei, free consultation, testing, repair, accessories are available, early repair, early start.

Related Product Types

If you found this article interesting, you may want to know more about these related product types. 

Contact Us to Maximize Your Profit

Enter part information below to check price and availability.

Usually ship by UPS or DHL with delivery around 3 working days.

All parts are tested OK before shipping out with a 12-month warranty.

Provide technology guidance service upon receiving the part.

CONTACT US
Thank you! Your message has been sent.
Unable to send your message. Please fix errors then try again.

Search